Digital Microscopes · Diagnostic Imaging · Custom Software
Digital Microscopes · Pro Imaging

UB-DM023P Polarised Glare-Control Microscope

The single biggest image-quality upgrade for reflective work. Slide the polarizer in and specular glare from solder, anodised metal and glossy coatings disappears — what is left is structure: grain, tool marks, cracks, residue.

Switchable polarizer Real 10–200× WiFi + USB Forensics-ready
UB-DM023P polarised USB digital microscope, 2MP sensor on aluminium stand
On/offPolarizer switch
10–200×Real optical zoom
2MP1080P output
8 LEDAdjustable ring

UB-DM023P at a glance

The UB-DM023P is a glare-control digital microscope: a 2 megapixel CMOS handheld with real 10–200× magnification and a switchable, rotatable polarizer. Sliding the filter in removes specular reflections from solder joints, anodised metal and glossy coatings, leaving grain, tool marks and cracks visible. Connects over WiFi or USB 2.0.

  • PolarizerSwitchable / rotatable, on-body
  • MagnificationReal 10–200×
  • Sensor2 MP CMOS · 1920×1080
  • ConnectionWiFi + USB 2.0
Overview

Turn the glare down, turn the detail up

Every polished surface fights back. Ring LEDs bounce straight off solder mask, brushed aluminium and cured resin, washing out exactly the features an inspector is paid to find. The DM023P attacks the problem optically — a rotatable polarizing filter on the body crosses out specular reflections before they ever reach the sensor.

The effect is not a filter preset. Grain structure in metals, subsurface cracks, flux residue and printed texture all gain contrast that software denoising cannot synthesise. And because the filter switches on the body, the same unit handles glossy coins at lunchtime and matte PCBs after — no second device.

  • Optical glare removal — contrast improvement at the sensor, not fake sharpness in software
  • Subsurface visibility — polarised light reveals layers and stress marks beneath glossy skins
  • One-slide workflow — compare polarised vs normal view in seconds for training and reports
  • Same platform as DM023A — shared accessories, stands and app ecosystem
Polariser comparison on a PCB — glare removed, chip markings fully readable
Specifications

UB-DM023P full specification

ModelUB-DM023P
MagnificationReal 10×–200×
Image sensor2 megapixel CMOS · 1920×1080
PolarizerSwitchable / rotatable, on-body
Illumination8× adjustable white LEDs
Focus rangeManual, 0–110 mm
ConnectionWiFi to smart devices / USB 2.0 to PC
Output resolution1080P / 720P / VGA
Battery18650 2000 mAh, replaceable
CertificationCE / FCC / RoHS
CustomisationOEM / ODM — logo, packaging, firmware, app
Warranty1 year
Applications

Shine a light, lose the shine

Metallurgy & machining

Tool marks, grain flow and heat-tint on polished or machined parts — contrast where flat lighting gives none.

Numismatics & artefacts

Die marks, doubling and surface wear on coins and artefacts — the difference between a grade and a guess.

Forensics

Reduced specular noise on questioned documents and trace evidence — pairs well with our IR model for layered examination.

UB-DM023P — commercial terms

UBOE is a B2B manufacturer and OEM/ODM partner. We supply distributors, own-brand sellers and clinic chains rather than end users, so a quotation is built around your market, volume and branding instead of being published as a list price. This is how the commercial side normally works.

  • Business modelB2B · OEM / ODM
  • Minimum orderSample → pilot → volume
  • Evaluation samplesOn request
  • Lead timeSet per milestone
  • CertificationCE · FCC · RoHS
  • PackagingNeutral or your brand

Neutral units can start from sample quantities. OEM branding typically begins at pilot-batch level, and a full ODM programme needs enough volume to amortise tooling. Tell us your target volume and we will confirm what is realistic rather than quote a number we cannot hold.

What we customise: logo and silk-screen, retail packaging, firmware defaults, splash screen, application branding, measurement workflow and ISP image tuning. Non-standard wavelengths are quoted per project.

Pricing is quoted per configuration, quantity and customisation scope. Send your target market, expected volume and required branding to [email protected].

FAQ

DM023P — common questions

Can the polarizer be turned off?

Yes — it slides and rotates on the barrel, so you can go from fully polarised to fully clear in one motion. Translucent or matte samples often image better with it off.

Is this the right choice for skin imaging?

Polarisation helps with skin too, but the dedicated UB-DM023B dermatoscope adds UV and clinical colour calibration. For clinics we recommend the DM023B; for general inspection with occasional skin use, the DM023P is fine.

Does polarisation cost resolution or speed?

No — it is a passive optical filter. Sensor resolution, frame rate and colour pipeline are identical to the non-polarised platform.

Related Products

Compare with

UB-DM023A

The non-polarised platform model — same body, same app ecosystem.

View details →

UB-DM020IR

Infrared variant — see beneath surfaces in a different spectrum.

View details →

UB-DM050U

5MP bench model — maximum resolution for the QC station.

View details →

Request UB-DM023P pricing

Tell us quantity and target market — we reply within one business day with tiers and lead time.

We verify every new contact. Enquiries are checked against a real company name and website before we quote — that is why we ask for your company details below. Marketing, SEO and web-design pitches are declined; genuine buyers get a reply within one business day.